mirror of
https://github.com/betaflight/betaflight-configurator.git
synced 2025-07-16 04:45:20 +03:00
Merge pull request #359 from basdelfos/battery_meter_type
Added dropdown for current and battery meter selection to configuration tab
This commit is contained in:
commit
acb7a84422
7 changed files with 410 additions and 212 deletions
|
@ -203,6 +203,21 @@ MspHelper.prototype.process_data = function(dataHandler) {
|
|||
MISC.vbatmaxcellvoltage = data.readU8() / 10; // 10-50
|
||||
MISC.vbatwarningcellvoltage = data.readU8() / 10; // 10-50
|
||||
break;
|
||||
case MSPCodes.MSP_VOLTAGE_METER_CONFIG:
|
||||
MISC.vbatscale = data.readU8(); // 10-200
|
||||
MISC.vbatmincellvoltage = data.readU8() / 10; // 10-50
|
||||
MISC.vbatmaxcellvoltage = data.readU8() / 10; // 10-50
|
||||
MISC.vbatwarningcellvoltage = data.readU8() / 10; // 10-50
|
||||
if (semver.gte(CONFIG.apiVersion, "1.23.0")) {
|
||||
MISC.batterymetertype = data.readU8();
|
||||
}
|
||||
break;
|
||||
case MSPCodes.MSP_CURRENT_METER_CONFIG:
|
||||
BF_CONFIG.currentscale = data.readU16();
|
||||
BF_CONFIG.currentoffset = data.readU16();
|
||||
BF_CONFIG.currentmetertype = data.readU8();
|
||||
BF_CONFIG.batterycapacity = data.readU16();
|
||||
break;
|
||||
case MSPCodes.MSP_3D:
|
||||
_3D.deadband3d_low = data.readU16();
|
||||
_3D.deadband3d_high = data.readU16();
|
||||
|
@ -342,6 +357,11 @@ MspHelper.prototype.process_data = function(dataHandler) {
|
|||
case MSPCodes.MSP_EEPROM_WRITE:
|
||||
console.log('Settings Saved in EEPROM');
|
||||
break;
|
||||
case MSPCodes.MSP_SET_CURRENT_METER_CONFIG:
|
||||
console.log('Current Settings saved');
|
||||
break;
|
||||
case MSPCodes.MSP_SET_VOLTAGE_METER_CONFIG:
|
||||
console.log('Voltage config saved');
|
||||
case MSPCodes.MSP_DEBUG:
|
||||
for (var i = 0; i < 4; i++)
|
||||
SENSOR_DATA.debug[i] = data.read16();
|
||||
|
@ -1009,7 +1029,21 @@ MspHelper.prototype.crunch = function(code) {
|
|||
.push8(Math.round(MISC.vbatmaxcellvoltage * 10))
|
||||
.push8(Math.round(MISC.vbatwarningcellvoltage * 10));
|
||||
break;
|
||||
|
||||
case MSPCodes.MSP_SET_VOLTAGE_METER_CONFIG:
|
||||
buffer.push8(MISC.vbatscale)
|
||||
.push8(Math.round(MISC.vbatmincellvoltage * 10))
|
||||
.push8(Math.round(MISC.vbatmaxcellvoltage * 10))
|
||||
.push8(Math.round(MISC.vbatwarningcellvoltage * 10));
|
||||
if (semver.gte(CONFIG.apiVersion, "1.23.0")) {
|
||||
buffer.push8(MISC.batterymetertype);
|
||||
}
|
||||
break;
|
||||
case MSPCodes.MSP_SET_CURRENT_METER_CONFIG:
|
||||
buffer.push16(BF_CONFIG.currentscale)
|
||||
.push16(BF_CONFIG.currentoffset)
|
||||
.push8(BF_CONFIG.currentmetertype)
|
||||
.push16(BF_CONFIG.batterycapacity)
|
||||
break;
|
||||
case MSPCodes.MSP_SET_RX_CONFIG:
|
||||
buffer.push8(RX_CONFIG.serialrx_provider)
|
||||
.push16(RX_CONFIG.maxcheck)
|
||||
|
|
Loading…