mirror of
https://github.com/betaflight/betaflight-configurator.git
synced 2025-07-23 16:25:22 +03:00
Replace API versions by constants
This commit is contained in:
parent
7fcc9efc72
commit
fd35031e6f
25 changed files with 315 additions and 301 deletions
|
@ -53,7 +53,7 @@ TABS.power.initialize = function (callback) {
|
|||
$('#content').load("./tabs/power.html", process_html);
|
||||
}
|
||||
|
||||
this.supported = semver.gte(FC.CONFIG.apiVersion, "1.33.0");
|
||||
this.supported = semver.gte(FC.CONFIG.apiVersion, API_VERSION_1_33);
|
||||
|
||||
if (!this.supported) {
|
||||
load_html();
|
||||
|
@ -226,7 +226,7 @@ TABS.power.initialize = function (callback) {
|
|||
var element = template.clone();
|
||||
destination.append(element);
|
||||
|
||||
if (semver.gte(FC.CONFIG.apiVersion, "1.41.0")) {
|
||||
if (semver.gte(FC.CONFIG.apiVersion, API_VERSION_1_41)) {
|
||||
$('input[name="mincellvoltage"]').prop('step','0.01');
|
||||
$('input[name="maxcellvoltage"]').prop('step','0.01');
|
||||
$('input[name="warningcellvoltage"]').prop('step','0.01');
|
||||
|
@ -237,7 +237,7 @@ TABS.power.initialize = function (callback) {
|
|||
$('input[name="warningcellvoltage"]').val(FC.BATTERY_CONFIG.vbatwarningcellvoltage);
|
||||
$('input[name="capacity"]').val(FC.BATTERY_CONFIG.capacity);
|
||||
|
||||
var haveFc = (semver.lt(FC.CONFIG.apiVersion, "1.35.0") || (FC.CONFIG.boardType == 0 || FC.CONFIG.boardType == 2));
|
||||
var haveFc = (semver.lt(FC.CONFIG.apiVersion, API_VERSION_1_35) || (FC.CONFIG.boardType == 0 || FC.CONFIG.boardType == 2));
|
||||
|
||||
var batteryMeterTypes = [
|
||||
i18n.getMessage('powerBatteryVoltageMeterTypeNone'),
|
||||
|
@ -264,7 +264,7 @@ TABS.power.initialize = function (callback) {
|
|||
currentMeterTypes.push(i18n.getMessage('powerBatteryCurrentMeterTypeVirtual'));
|
||||
currentMeterTypes.push(i18n.getMessage('powerBatteryCurrentMeterTypeEsc'));
|
||||
|
||||
if (semver.gte(FC.CONFIG.apiVersion, "1.36.0")) {
|
||||
if (semver.gte(FC.CONFIG.apiVersion, API_VERSION_1_36)) {
|
||||
currentMeterTypes.push(i18n.getMessage('powerBatteryCurrentMeterTypeMsp'));
|
||||
}
|
||||
}
|
||||
|
@ -491,7 +491,7 @@ TABS.power.initialize = function (callback) {
|
|||
}
|
||||
|
||||
function save_voltage_config() {
|
||||
if (semver.gte(FC.CONFIG.apiVersion, "1.36.0")) {
|
||||
if (semver.gte(FC.CONFIG.apiVersion, API_VERSION_1_36)) {
|
||||
mspHelper.sendVoltageConfig(save_amperage_config);
|
||||
} else {
|
||||
MSP.send_message(MSPCodes.MSP_SET_VOLTAGE_METER_CONFIG, mspHelper.crunch(MSPCodes.MSP_SET_VOLTAGE_METER_CONFIG), false, save_amperage_config);
|
||||
|
@ -499,7 +499,7 @@ TABS.power.initialize = function (callback) {
|
|||
}
|
||||
|
||||
function save_amperage_config() {
|
||||
if (semver.gte(FC.CONFIG.apiVersion, "1.36.0")) {
|
||||
if (semver.gte(FC.CONFIG.apiVersion, API_VERSION_1_36)) {
|
||||
mspHelper.sendCurrentConfig(save_to_eeprom);
|
||||
} else {
|
||||
MSP.send_message(MSPCodes.MSP_SET_CURRENT_METER_CONFIG, mspHelper.crunch(MSPCodes.MSP_SET_CURRENT_METER_CONFIG), false, save_to_eeprom);
|
||||
|
|
Loading…
Add table
Add a link
Reference in a new issue