1
0
Fork 0
mirror of https://github.com/betaflight/betaflight.git synced 2025-07-15 20:35:33 +03:00

Update serial_cli.c

When using a voltage sensor instead of direct connection for voltage monitoring, vbat_scale max limit is too low. It should be raised to a value greater than 200 (250 or more)
This commit is contained in:
airmamaf 2014-10-03 09:15:48 +02:00
parent 98f5bdd986
commit 720486a4de

View file

@ -264,7 +264,7 @@ const clivalue_t valueTable[] = {
{ "telemetry_switch", VAR_UINT8 | MASTER_VALUE, &masterConfig.telemetryConfig.telemetry_switch, 0, 1 },
{ "frsky_inversion", VAR_UINT8 | MASTER_VALUE, &masterConfig.telemetryConfig.frsky_inversion, 0, 1 },
{ "vbat_scale", VAR_UINT8 | MASTER_VALUE, &masterConfig.batteryConfig.vbatscale, 10, 200 },
{ "vbat_scale", VAR_UINT8 | MASTER_VALUE, &masterConfig.batteryConfig.vbatscale, 10, 250 },
{ "vbat_max_cell_voltage", VAR_UINT8 | MASTER_VALUE, &masterConfig.batteryConfig.vbatmaxcellvoltage, 10, 50 },
{ "vbat_min_cell_voltage", VAR_UINT8 | MASTER_VALUE, &masterConfig.batteryConfig.vbatmincellvoltage, 10, 50 },
{ "current_meter_scale", VAR_UINT16 | MASTER_VALUE, &masterConfig.batteryConfig.currentMeterScale, 1, 10000 },