mirror of
https://github.com/betaflight/betaflight.git
synced 2025-07-16 21:05:35 +03:00
Merge pull request #1614 from mikeller/adjust_current_meter_settings
Adjusted current meter setting ranges to allow for negative offset. Also added biquad filter for current and did some cleanup.
This commit is contained in:
commit
82e78bc249
3 changed files with 69 additions and 48 deletions
|
@ -789,8 +789,8 @@ const clivalue_t valueTable[] = {
|
|||
{ "vbat_min_cell_voltage", VAR_UINT8 | MASTER_VALUE, &masterConfig.batteryConfig.vbatmincellvoltage, .config.minmax = { 10, 50 } },
|
||||
{ "vbat_warning_cell_voltage", VAR_UINT8 | MASTER_VALUE, &masterConfig.batteryConfig.vbatwarningcellvoltage, .config.minmax = { 10, 50 } },
|
||||
{ "vbat_hysteresis", VAR_UINT8 | MASTER_VALUE, &masterConfig.batteryConfig.vbathysteresis, .config.minmax = { 0, 250 } },
|
||||
{ "current_meter_scale", VAR_INT16 | MASTER_VALUE, &masterConfig.batteryConfig.currentMeterScale, .config.minmax = { -10000, 10000 } },
|
||||
{ "current_meter_offset", VAR_UINT16 | MASTER_VALUE, &masterConfig.batteryConfig.currentMeterOffset, .config.minmax = { 0, 3300 } },
|
||||
{ "current_meter_scale", VAR_INT16 | MASTER_VALUE, &masterConfig.batteryConfig.currentMeterScale, .config.minmax = { -16000, 16000 } },
|
||||
{ "current_meter_offset", VAR_INT16 | MASTER_VALUE, &masterConfig.batteryConfig.currentMeterOffset, .config.minmax = { -16000, 16000 } },
|
||||
{ "multiwii_current_meter_output", VAR_UINT8 | MASTER_VALUE | MODE_LOOKUP, &masterConfig.batteryConfig.multiwiiCurrentMeterOutput, .config.lookup = { TABLE_OFF_ON } },
|
||||
{ "current_meter_type", VAR_UINT8 | MASTER_VALUE | MODE_LOOKUP, &masterConfig.batteryConfig.currentMeterType, .config.lookup = { TABLE_CURRENT_SENSOR } },
|
||||
{ "battery_notpresent_level", VAR_UINT8 | MASTER_VALUE, &masterConfig.batteryConfig.batterynotpresentlevel, .config.minmax = { 0, 200 } },
|
||||
|
|