mirror of
https://github.com/iNavFlight/inav.git
synced 2025-07-19 22:35:19 +03:00
Fix CLI parameter declaration for baro and PIDs
This commit is contained in:
parent
68abea6a04
commit
ed0f85c41b
1 changed files with 1 additions and 9 deletions
|
@ -642,7 +642,7 @@ const clivalue_t valueTable[] = {
|
|||
{ "acc_soft_filter", VAR_UINT8 | PROFILE_VALUE, &masterConfig.profile[0].acc_soft_filter, .config.minmax = { 0, 3 }, 0 },
|
||||
|
||||
{ "baro_tab_size", VAR_UINT8 | PROFILE_VALUE, &masterConfig.profile[0].barometerConfig.baro_sample_count, .config.minmax = { 0, BARO_SAMPLE_COUNT_MAX }, 0 },
|
||||
{ "baro_noise_lpf", VAR_FLOAT | PROFILE_VALUE | MODE_LOOKUP, &masterConfig.profile[0].barometerConfig.baro_noise_lpf, .config.lookup = { TABLE_OFF_ON }, 0 },
|
||||
{ "baro_noise_lpf", VAR_FLOAT | PROFILE_VALUE, &masterConfig.profile[0].barometerConfig.baro_noise_lpf, .config.minmax = { 0, 1 }, 0 },
|
||||
{ "baro_hardware", VAR_UINT8 | MASTER_VALUE, &masterConfig.baro_hardware, .config.minmax = { 0, BARO_MAX }, 0 },
|
||||
|
||||
{ "mag_hardware", VAR_UINT8 | MASTER_VALUE, &masterConfig.mag_hardware, .config.minmax = { 0, MAG_MAX }, 0 },
|
||||
|
@ -675,18 +675,10 @@ const clivalue_t valueTable[] = {
|
|||
{ "level_angle", VAR_FLOAT | PROFILE_VALUE, &masterConfig.profile[0].pidProfile.A_level, .config.minmax = { 0, 10 }, 0 },
|
||||
{ "sensitivity_horizon", VAR_UINT8 | PROFILE_VALUE, &masterConfig.profile[0].pidProfile.H_sensitivity, .config.minmax = { 0, 250 }, 0 },
|
||||
|
||||
{ "p_alt", VAR_UINT8 | PROFILE_VALUE, &masterConfig.profile[0].pidProfile.P8[PIDALT], .config.minmax = { 0, 200 }, 0 },
|
||||
{ "i_alt", VAR_UINT8 | PROFILE_VALUE, &masterConfig.profile[0].pidProfile.I8[PIDALT], .config.minmax = { 0, 200 }, 0 },
|
||||
{ "d_alt", VAR_UINT8 | PROFILE_VALUE, &masterConfig.profile[0].pidProfile.D8[PIDALT], .config.minmax = { 0, 200 }, 0 },
|
||||
|
||||
{ "p_level", VAR_UINT8 | PROFILE_VALUE, &masterConfig.profile[0].pidProfile.P8[PIDLEVEL], .config.minmax = { 0, 200 }, 0 },
|
||||
{ "i_level", VAR_UINT8 | PROFILE_VALUE, &masterConfig.profile[0].pidProfile.I8[PIDLEVEL], .config.minmax = { 0, 200 }, 0 },
|
||||
{ "d_level", VAR_UINT8 | PROFILE_VALUE, &masterConfig.profile[0].pidProfile.D8[PIDLEVEL], .config.minmax = { 0, 200 }, 0 },
|
||||
|
||||
{ "p_vel", VAR_UINT8 | PROFILE_VALUE, &masterConfig.profile[0].pidProfile.P8[PIDVEL], .config.minmax = { 0, 200 }, 0 },
|
||||
{ "i_vel", VAR_UINT8 | PROFILE_VALUE, &masterConfig.profile[0].pidProfile.I8[PIDVEL], .config.minmax = { 0, 200 }, 0 },
|
||||
{ "d_vel", VAR_UINT8 | PROFILE_VALUE, &masterConfig.profile[0].pidProfile.D8[PIDVEL], .config.minmax = { 0, 200 }, 0 },
|
||||
|
||||
{ "dterm_cut_hz", VAR_UINT8 | PROFILE_VALUE, &masterConfig.profile[0].pidProfile.dterm_cut_hz, .config.minmax = {0, 200 }, 0 },
|
||||
{ "pterm_cut_hz", VAR_UINT8 | PROFILE_VALUE, &masterConfig.profile[0].pidProfile.pterm_cut_hz, .config.minmax = {0, 200 }, 0 },
|
||||
|
||||
|
|
Loading…
Add table
Add a link
Reference in a new issue