mirror of
https://github.com/iNavFlight/inav.git
synced 2025-07-24 00:35:34 +03:00
Battery.md docs fixes and improvement.
This commit is contained in:
parent
3a5e34e659
commit
e63d859cf7
1 changed files with 8 additions and 7 deletions
|
@ -22,6 +22,7 @@ When dealing with batteries **ALWAYS CHECK POLARITY!**
|
|||
Measure expected voltages **first** and then connect to the flight controller. Powering the flight controller with
|
||||
incorrect voltage or reversed polarity will likely fry your flight controller. Ensure your flight controller
|
||||
has a voltage divider capable of measuring your particular battery voltage.
|
||||
On the first battery connection is always advisable to use a current limiter device to limit damages if something is wrong in the setup.
|
||||
|
||||
### Naze32
|
||||
|
||||
|
@ -53,19 +54,19 @@ Configure min/max cell voltages using the following CLI setting:
|
|||
|
||||
`vbat_scale` - Adjust this to match actual measured battery voltage to reported value.
|
||||
|
||||
`vbat_max_cell_voltage` - Maximum voltage per cell, used for auto-detecting battery voltage in 0.1V units, i.e. 43 = 4.3V
|
||||
`vbat_max_cell_voltage` - Maximum voltage per cell, used for auto-detecting battery voltage in 0.01V units, i.e. 430 = 4.30V
|
||||
|
||||
`set vbat_warning_cell_voltage` - Warning voltage per cell; this triggers battery-out alarms, in 0.1V units, i.e. 34 = 3.4V
|
||||
`set vbat_warning_cell_voltage` - Warning voltage per cell; this triggers battery-out alarms, in 0.01V units, i.e. 340 = 3.40V
|
||||
|
||||
`vbat_min_cell_voltage` - Minimum voltage per cell; this triggers battery-out alarms, in 0.1V units, i.e. 33 = 3.3V
|
||||
`vbat_min_cell_voltage` - Minimum voltage per cell; this triggers battery-out alarms, in 0.01V units, i.e. 330 = 3.30V
|
||||
|
||||
e.g.
|
||||
|
||||
```
|
||||
set vbat_scale = 110
|
||||
set vbat_max_cell_voltage = 43
|
||||
set vbat_warning_cell_voltage = 34
|
||||
set vbat_min_cell_voltage = 33
|
||||
set vbat_scale = 1100
|
||||
set vbat_max_cell_voltage = 430
|
||||
set vbat_warning_cell_voltage = 340
|
||||
set vbat_min_cell_voltage = 330
|
||||
```
|
||||
|
||||
# Current Monitoring
|
||||
|
|
Loading…
Add table
Add a link